PORTABLE  OVERCURRENT   RELAYTEST KIT
(Secondary  Injection  Kit)Model:  RLY – 108

FEATURES: Single  Kit with two  units

•   Two separate  inputs  & five outputs

•   Test outputs  available:

Unit –  I : 0 to 100 A, AC, 0 to 240 voltsAC

Unit –  II: 0 to 2 A AC, 0 to 240 volts AC and aux.

o to 240 volts  DC.

•   Panel  with clear and easy to follow  legend.

•   Built in TImer for testing  relays  and circuit  breakers.

•   Overload  protection.

•   Independent   Digital  readouts  of current,  voltage  and  time.

•   The kit can be used for all types  of relays  (current  and voltage  relays

I Low current  C.T) except  6 current  differential  relay & Distance  relays

•  Weight:   22 kegs. Approx

By using our RelayTest  Kit following  relays can be tested

Description

•  Over current  relay

•  IDMT over current relay

•  Under current

•  Earth fault relay

•  Over Voltage relay

•  Under voltage relay

•  Differential relay

•  Negative sequence relay

•  Synchronizing  check relay

•  Single Pole circuit Breaker timing

•  Checking or interlocking relay

•  A.C redosing  relay

•   Field Failure Relay

•   Reverse phase or phase balance current relay

•   Bearing protective relay

•   Instantaneous  over current or rate-of-rise  relay

•  Circuit breaker auxiliary switch normally closed

•  Trip coil supervision  relay

•  Over nux relay

•  Auxiliary relay

•  TIme delay stopping or opening relay

(Break failure)

•  Blocking relay

•  Lock out relay

•  Voltage or current balance relay    •  A.C time over current relay

•  Automatic  selective control or transfer relay

•  Thermal  relay

•  TIme delay relay

•  Circuit breaker auxiliary switch normally open

UNIT – I

•  All Types of Electro Magnetic

I Static relays

SUPPLY VOLTAGE        230 Volts,  50 Hz, (± 10%), AC Single Phase supply through Toggle switch & Control Fuse for Units 1 & 2.

OUTPUT                          1. Variable current Application  0 –  100AAC

2. For voltage, the Variac output is connected  to variable voltage output 0 –  230 V AC with fuse.

3. Separate  current output terminals and separate voltage output terminals  are provided

(At one time either current or voltage circuit will be connected  through a Toggle Switch)

CONTROLS                       1. 1st Unit with Push Button Control Only. When the ON/OFF push button is operated, all outputs will be connected  to the output connectors

2. 2nd unit with Push Button controt  & By-Pass Switch

CURRENT  OUTPUT   :  Output;  0 –  100A-  50A-   25A-   10A – 5A-   1A

Each of these outputs has a separate terminal referred to one common terminal.

Each current output terminal is for 400 VA capacity, except 1A output which is for 250 VA capacity

VOLTAGE  OUTPUT RATING

AMMETER

VOLTMETER

PROTECTION TIME INTERVAL

METER

External  Timer

:  0·230 V AC 12A – Variable voltage output through fuse units Separate pair of test terminals  is provided

Continuous (3min ON 110 Min. OFF)

3 Yo Digit, 12mm LED type. Accuracy:  ± 1% (Direct reading 0 –  SOA) For current ranges of 1A, SA, lOA,

2SA and SOAAC, readings can be noted direclly  from the digital ammeter. Above SOAmps & up to

100Amps readings can be taken through external clamp meter.

3 y, Digit, 12mm LED type. Accuracy:±  1 % (Common meter for measurement  of Unit·l  & Unit-2 AC

& Unit-2 DC output through a 3 position selector switch)

a. Unit 1 :- Output is 0 -230  V AC. Voltmeter connected through selector switch (Switch Positicn-f  )

b. Unit 2 ;·Output is O· 230 V AC. Voltmeter connected  through Selector switch. (Switch  Positton-z)

c. Unit 2 ;- DC output 0 -2S0 V DC. Volt meter connected  through selector Switch (Switch Posiuon-S) Anyone   voltage only can be read at a time.

Control Fuse for Mains input and all outputs (current I Voltage)

5 Digit. 12 mm LED. crystal time base.

One five digit timer with toggle selector for NO/NC (for checking the opening and closing time) in mil!i second. The four position timer selection is provided  for auto ranges (NO/NC test terminals. reset push button are also provided)

Multi-ranqe:  a) 99.999 seconds  b) 999.99 seconds c) 9999.9 seconds d) 99999. seconds

The timer will stop on getting the signal from the relay. When the timer stops the current and voltage output is de –  energized Separate  pair of test terminals (Relay trip contacts) is provided

tor checking breaker opening and closing time

UNIT 2

SUPPLY VOLTAGE     :  230± 10% Volts. 50/60   Hz. AC Single Phase.

SELECTION (MODE)

BY • PASS MODE CONTROL  MODE

CURRENT  OUTPUT

A.CVOLTAGE OUTPUT

D.CVOLTAGE OUTPUT

RATING PROTECTION CONSTRUCTION DIMENSIONS WEIGHT

: All Outputs are connected through by – pass I control mode switch

:  It “By pass” • mode is chosen then all outputs will be directly connected  to the output terminals.  In this option Timer is in “OFF” mode & “ON I OFF” Push button control is in ‘OFF”  position.

:  If ‘Push  button” control mode is chosen then all outputs will be connected to the output terminals through the “ON/OFF”  push button. according to the selection.  In this option timer is in ‘ON”  mode.

:  0 to 2AAC  (Measured  by external Clamp meter)

:  0 –  230 V AC With 2A control fuse.

0·250 V DC output through 1.5 A fuse. filtering condenser and bleeder resistor

Continuous

Fuse for Mains Input and all Outputs

Powder coated MS Box with Carrying handle. W x 0 x H: 17.5″ x 13″ x 7.5″ approx.

23 kgs.approx.